| 00 | System OK, vehicle moving |
| 01 | 1A sensor/wiring open circuit or short circuit |
| 02 | 1B sensor/wiring open circuit or short circuit |
| 03 | 2A sensor/wiring open circuit or short circuit |
| 04 | 2B sensor/wiring open circuit or short circuit |
| 05 | 3A sensor/wiring open circuit or short circuit |
| 06 | 3B sensor/wiring open circuit or short circuit |
| 07 | System OK, vehicle not moving |
| 08 | Retarder relay/wiring open circuit |
| 09 | Retarder relay/wiring short circuit |
| 0A | COLAS solenoid/wiring open circuit |
| 0C | COLAS solenoid/wiring short circuit |
| 0E | Warning lamp circuit fault |
| 11 | 1A sensor system low output |
| 12 | 1B sensor system low output |
| 13 | 2A sensor system low output |
| 14 | 2B sensor system low output |
| 15 | 3A sensor system low output |
| 16 | 3B sensor system low output |
| 20 | Exciter type incorrect |
| 21 | 1A sensor system intermittent low output |
| 22 | 1B sensor system intermittent low output |
| 23 | 2A sensor system intermittent low output |
| 24 | 2B sensor system intermittent low output |
| 25 | 3A sensor system intermittent low output |
| 26 | 3B sensor system intermittent low output |
| 37 | Lamp signalled by external device |
| 40 | Sensor wiring crossed across an axle |
| 41 | Slow recovery of one wheel of red channel |
| 42 | Slow recovery of one wheel of blue channel |
| 43 | Slow recovery of one wheel of yellow channel |
| 61 | Hold solenoid open circuit red |
| 62 | Hold solenoid open circuit blue |
| 63 | Hold solenoid open circuit yellow |
| 67 | Dump solenoid open circuit red |
| 68 | Dump solenoid open circuit blue |
| 69 | Dump solenoid open circuit yellow |
| 71 | Hold solenoid short circuit red |
| 72 | Hold solenoid short circuit blue |
| 73 | Hold solenoid short circuit yellow |
| 77 | Dump solenoid short circuit red |
| 78 | Dump solenoid short circuit blue |
| 79 | Dump solenoid short circuit yellow |
| 80 | Modulator poor insulation or wiring fault |
| 81 | Hold solenoid B+ short circuit red |
| 82 | Hold solenoid B+ short circuit blue |
| 83 | Hold solenoid B+ short circuit yellow |
| 87 | Dump solenoid B+ short circuit red |
| 88 | Dump solenoid B+ short circuit blue |
| 89 | Dump solenoid B+ short circuit yellow |
| 90 | Supply voltage low, < 18 volts |
| 91 | ISO 7638 pin 1 power supply bad, or fuse blown |
| 92 | Supply voltage high, > 32 volts |
| 93 | Internal ECU fault 93 |
| 99 | Internal ECU fault 99 |
| A1 | Reset to ride height |
| A2 | Retarder |
| CF | Sensors and solenoid not connected |